HOME ICD800
ICD-800 2/3" CCD

Color CCD Camera


 

The ICD-800 single chip, high resolution, high sensitivity color camera promises performance unsurpassed by any existing color chip technology. Durable, dependable and reliable are only a few ways to describe the ICD-800. The automatic white balance circuit has the backup function of memory. Once the white balance is adjusted, it is retained for about eight hours even if the power is down. Sharp color reproduction, no lag, continuous white bal- ance through the lens and 24VAC line lock qualifies the ICD-800 for any security, industrial, medical or robotic application.

  • Through-the-lens continuous white balance
  • 24VAC line lock
  • 330 TV lines resolution
  • No color distortion
  • No lag/burning/streaking
  • Genlockable (BNC}
  • Auto-iris standard
  • SPECIFICATIONS
    Resolution Horizontal: 330 TV lines
    Vertical: 350 TV lines
    Pick-up Device Interline transfer CCD
    Color Filter Ye. Cy, Mg, G color compensation method
    Picture Element 510(H) x 490(V) pixels
    Sensing Area 8.8(H) x 6.6(V)mm (2/3")
    Scanning System 525 lines, 60 fields per 30 frames,
    2:1 interface. Conforming to NTSC method
    Scanning Frequency H: 15.734kHz, V: 59.94Hz
    Sync System Internal: Crystal oscillation
    External: Genlock with a VBS or BBS input
    Internal or external is switched automatically.
    Line lock (24VAC version)
    NTSC/line lock switchable
    Genlock Input: VBS 1.0V p-p, 75 ohms, or BBS 0.45V p-p, 75 ohms
    Video Output Composite: VBS 1.0V p-p, 75 ohms, one output channel
    Signal-to-Noise Ratio 47dB p-plrms (luminance signal)
    Using f/4 1000 lux, 4.2MHz LPF
    Standard Object Illuminance f/4, 1000 lux (100fc)/3200°K, reflection ratio of 89.9%
    Minimum Object Illuminance f/1.2 , about 10 lux (1.0fc)/3200°K, reflection ratio of 89.9%
    Automatic Iris Circuit Built-in
    Automatic White Balance Circuit Built-in
    Lens Mount C mount
    Camera Mount 1/4" , 20UNC (top and bottom panels)
    Connectors Video Out: BNC type x 1
    Genlock: BNC type x 1
    12VDC: 4-pin connector x 1 (12VDC type)
    A.I.: 3-pin connector x 1
    AC Adaptor (optional) Mode Name: AC-800 120VAC
    (12VDC type) input
    12VDC, 0.45A output
    Power Supply 12VDC ± 1V, approx. 0.45A
    24VAC (24VAC version)
    Power Consumption 5.4W approx.
    8W (24VAC version)
    Operating Temperature -5°C to +45°C
    Dimensions 65(H) x 75(W) x 165(D)mm
    100(H) x 75(W) x 165(D)mm (24VAC version)
    Weight 800g approx.
    Design and specifications are subject to change without notice.
    Home | All Products | Contact | Site Map